Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur J Radiol ; 81(7): 1405-12, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21458939

RESUMO

OBJECTIVE: Quantitative image quality assessment in terms of image noise (IN), contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) in relation to required radiation dose (RD) for dual-energy (DE), standard and low-kVp contrast-enhanced computed-tomography (CT) cholangiography. MATERIALS AND METHODS: For each of 22 DECT-cholangiography examinations, 3 image datasets were analyzed as independent single-source CT-acquisitions at different tube potential, i.e. 80 kVp, 120 kVp-equivalent (linear blended dataset M0.3: 30% 80 kVp, 70% 140 kVp), and 140 kVp. Analysis comprised determination of IN, CNR and SNR in regions of interest (ROI) placed in liver parenchyma and contrasted bile ducts. IN was evaluated as mean standard deviation of 3 ROI placed within liver parenchyma (segments 6/7, 5/8, 2/3); CNR was assessed as bile duct-to-liver parenchyma ratio, and SNR as bile duct-to-image noise ratio. RD in terms of CT dose index (CTDI(vol)), dose-length product (DLP) and effective dose (ED) has been determined for each of the datasets, and compared to console prediction and scan summary values. Using phantom measurements of CTDI(vol), a method for separating comprehensive RD values of DE-acquisitions into the original RD contribution of each tube (80 kVp/140 kVp) has been developed, enabling comparison of all 3 datasets as if independently acquired using single-source "single-energy" technique. RESULTS: Highest IN was detected for 80 kVp- (38.6 ± 5.1HU), lowest for 120 kVp-equivalent linear blended M0.3-datasets (23.1 ± 3.4HU) with significant differences between all datasets (P<0.001). Highest SNR and CNR were measured for M0.3- (SNR: 14.8 ± 4.1; CNR: 11.6 ± 3.8) and 80 kVp-datasets (SNR: 13.8 ± 4.8; CNR: 11.2 ± 4.5); lowest for 140 kVp-datasets (SNR: 9.5 ± 2.5; CNR: 7.1 ± 2.3) with significant differences between M0.3- and 140 kVp-datasets as well as between 80 kVp- and 140 kVp-datasets (both P<0.001 for both CNR, SNR). CTDI(vol), DLP and ED were reduced by 50% for low-kilovoltage acquisitions (CTDI(vol): 5.5 ± 1.4 mGy; DLP: 127.8 ± 40.1 mGy cm; ED: 1.9 ± 0.6 mSv) compared to comprehensive DE-acquisitions (CTDI(vol): 11.0 ± 2.3 mGy; DLP: 253.8 ± 67.5 mGy cm; ED: 3.8 ± 1.0 mSv, tube contribution: 80 kVp: 44.5%; 140 kVp: 55.5%), and by 20% compared to conventional acquisitions at 120 kVp (CTDI(vol): 6.71 mGy; DLP: 153.5 ± 16.9 mGy cm; ED: 2.3 ± 0.3 mSv). CONCLUSIONS: Despite higher IN, low-kilovoltage CT-cholangiography reveals no significant difference with respect to CNR and SNR when compared to linear blended images yielded by DECT. Compared to DECT or conventional CT at 120 kVp, contrast-enhanced low-kVp CT cholangiography potentially allows reduction of patient dose by up to 50% or 20%, respectively. Therefore, CT-cholangiography at 80 kVp should be considered as an alternative to DECT-cholangiography whenever DECT is unavailable, or if increased image quality of DECT regarding quantitative bile duct evaluation is not needed for diagnosis.


Assuntos
Colangiografia/métodos , Transplante de Fígado , Doadores Vivos , Tomografia Computadorizada por Raios X/métodos , Adulto , Análise de Variância , Meios de Contraste/administração & dosagem , Feminino , Humanos , Iodopamida/administração & dosagem , Iodopamida/análogos & derivados , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Estudos Retrospectivos , Razão Sinal-Ruído
2.
Eur J Radiol ; 81(9): 2007-13, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21696902

RESUMO

PURPOSE: To prospectively evaluate whether intravenous morphine co-medication improves bile duct visualization of dual-energy CT-cholangiography. MATERIALS AND METHODS: Forty potential donors for living-related liver transplantation underwent CT-cholangiography with infusion of a hepatobiliary contrast agent over 40 min. Twenty minutes after the beginning of the contrast agent infusion, either normal saline (n=20 patients; control group [CG]) or morphine sulfate (n=20 patients; morphine group [MG]) was injected. Forty-five minutes after initiation of the contrast agent, a dual-energy CT acquisition of the liver was performed. Applying dual-energy post-processing, pure iodine images were generated. Primary study goals were determination of bile duct diameters and visualization scores (on a scale of 0 to 3: 0--not visualized; 3--excellent visualization). RESULTS: Bile duct visualization scores for second-order and third-order branch ducts were significantly higher in the MG compared to the CG (2.9±0.1 versus 2.6±0.2 [P<0.001] and 2.7±0.3 versus 2.1±0.6 [P<0.01], respectively). Bile duct diameters for the common duct and main ducts were significantly higher in the MG compared to the CG (5.9±1.3 mm versus 4.9±1.3 mm [P<0.05] and 3.7±1.3 mm versus 2.6±0.5 mm [P<0.01], respectively). CONCLUSION: Intravenous morphine co-medication significantly improved biliary visualization on dual-energy CT-cholangiography in potential donors for living-related liver transplantation.


Assuntos
Absorciometria de Fóton/métodos , Colangiografia/métodos , Seleção do Doador/métodos , Transplante de Fígado/diagnóstico por imagem , Morfina/administração & dosagem , Tomografia Computadorizada por Raios X/métodos , Analgésicos Opioides/administração & dosagem , Ductos Biliares , Meios de Contraste/administração & dosagem , Feminino , Humanos , Aumento da Imagem/métodos , Injeções Intravenosas , Doadores Vivos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
3.
Eur Surg Res ; 45(1): 26-33, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20720430

RESUMO

BACKGROUND/AIMS: To determine whether intravenous morphine comedication improves bile duct visualization, diameter and/or volume applying intravenous CT cholangiography in a porcine liver model. METHODS: 12 Landrace pigs underwent intravenous CT cholangiography. Eight minutes after initiation of the contrast material infusion, either morphine sulfate (n = 6 animals) or normal saline (n = 6 animals) was administered. Eighteen consecutive CT scans of the liver were acquired with 2-min intervals starting with initiation of the contrast material infusion. Maximum bile duct visualization scores, diameters and volumes and time to maximum bile duct visualization scores, diameters and volumes were determined. RESULTS: Maximum bile duct visualization scores, diameters and volumes and time to maximum bile duct visualization scores, diameters and volumes were not significantly different when the morphine group was compared to the normal saline group. Maximum bile duct visualization scores ranged between 4.00 ± 0.00 and 2.83 ± 1.47. Maximum bile duct diameters ranged between 6.77 ± 0.40 and 2.10 ± 1.35 mm. Maximum bile duct volume was 16.41 ± 7.33 ml in the morphine group and 16.79 ± 5.65 ml in the normal saline group. CONCLUSION: Intravenous morphine comedication failed to improve bile duct visualization and to increase bile duct diameter and volume applying CT cholangiography.


Assuntos
Morfina/administração & dosagem , Analgésicos Opioides/administração & dosagem , Animais , Colecistografia/métodos , Ducto Colédoco/anatomia & histologia , Ducto Colédoco/diagnóstico por imagem , Ducto Cístico/diagnóstico por imagem , Infusões Intravenosas , Radiografia Abdominal , Suínos , Tomografia Computadorizada por Raios X/métodos
4.
J Hepatobiliary Pancreat Sci ; 17(5): 666-72, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20703845

RESUMO

BACKGROUND/PURPOSE: To assess the feasibility of intravenous 64-multi-detector row computed tomography (CT)-cholangiography of porcine livers with definition of the temporal window for optimal bile duct delineation. METHODS: Six healthy Landrace pigs, each weighing 28.97 +/- 2.99 kg, underwent 64-multi-detector row CT-cholangiography. Each pig was infused with 50 ml of meglumine iotroxate continuously over a period of 20 min and, starting with the initiation of the infusion, 18 consecutive CT scans of the abdomen at 2-min intervals were acquired. All series were evaluated for bile duct visualization scores and maximum bile duct diameters as primary study goals and bile duct attenuation and liver enhancement as secondary study goals. RESULTS: Of the 16 analyzed biliary tract segments, maximum bile duct visualization scores ranged between 4.00 +/- 0.00 and 2.83 +/- 1.47. Time to maximum bile duct visualization scores ranged between 10 and 34 min. Average bile duct visualization scores for the 10- to 34-min interval ranged between 3.99 +/- 0.05 and 2.78 +/- 0.10. Maximum bile duct diameters ranged between 6.47 +/- 1.05 and 2.65 +/- 2.23 mm. Time to maximum bile duct diameters ranged between 24 and 34 min. Average bile duct diameters for the 10- to 34-min interval ranged between 6.00 +/- 0.38 and 2.40 +/- 0.13 mm. CONCLUSIONS: Intravenous 64-multi-detector row CT-cholangiography of non-diseased porcine liver is feasible, with the best bile duct delineation acquired between 10 and 34 min after initiation of the contrast agent infusion.


Assuntos
Ductos Biliares Intra-Hepáticos/diagnóstico por imagem , Colangiografia/métodos , Meios de Contraste/administração & dosagem , Iodopamida/análogos & derivados , Hepatopatias/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Animais , Modelos Animais de Doenças , Estudos de Viabilidade , Iodopamida/administração & dosagem , Hepatopatias/cirurgia , Reprodutibilidade dos Testes , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...